Scientific paper ID 776 : 2013/2
EXAMINATION OF WELDED JOINT FROM THE COOLING SYSTEM OF PHOTOVOLTAIC INSTALLATION

Stefan Christov, Plamen Tashev, Seryoja Valkanov

The quality of a welded joint in expansion tank of the water cooling system of a photovoltaic installation is identified. A lot of flaws are found after analyzing the macro- and micro structure, and the chemical content of the welded joint. The incorrectly followed mode of welding with high linear energy has resulted in high residual welding stresses, overheating of the metal and continued detention at high temperature. Thus the corrosion resistance of the metal in the heat affected zone (HAZ) decreases and this is the most likely reason for corrosion and cracking.


заваряване заварено съединение неръждясваща стомана фотоволтаична инсталация разширителен съд несъвършенства корозия макро- и микроструктураWelding welded joint stainless steel photovoltaic installation expansion vessel flaws corrosion macrStefan Christov Plamen Tashev Seryoja Valkanov

BIBLIOGRAPHY

[1] Metals Handbook, Volume 9 - Metallography and microstructures, American Society for Metals, Handbook Committee, ISBN 0-87170-007-7 (v. 1), Printed in the United States of America

[2] Metals Handbook, Volume 6 - Welding, brazing and soldering, American Society for Metals, Handbook Committee, ISBN 0-87170-377-7(V.1), Printed in the United States of America

[3] ISO 5817 (БДС EN 25817)

 

 

 